Charged EVs | The right way to design dependable automotive management electronics for next-gen autos


Sponsored by Littelfuse, Inc.

Making certain circuit survival within the difficult automotive and electrical automobile environments.

As automobile electrification grows and provides capabilities, the digital management structure should evolve to handle operations effectively, responsively, and safely. The structure is shifting from a easy distributed system to a zonal management system, the place zonal management models handle close by ECUs, simplifying wiring and lowering automobile weight. Automotive Ethernet is the principle protocol for zonal management.

The zonal management unit is essential for your entire automobile, requiring strong safety towards overcurrent, transient voltages, and ESD. Defending Ethernet strains ensures dependable communication and information integrity. This text guides designers in choosing parts to safeguard zonal controller circuits and communication strains, enhancing automotive electronics‘ reliability.

The evolution of automotive management architectures

Automotive architectures should adapt as vehicle electrification grows. Excessive-end autos could now have as much as 150 ECUs, with options like autonomous driving including extra complexity. The rising variety of ECUs strains the distributed management structure, the place every ECU communicates by way of a central gateway, creating bottlenecks.

Determine 1. The evolution of automotive management architectures

To ease these calls for, a site construction was developed, grouping frequent capabilities like powertrain and lighting below area controllers. Nevertheless, this will complicate wiring as a result of distance between capabilities.

The superior zonal management construction makes use of zonal management models to handle capabilities inside particular automobile zones, enabling extra software-defined performance. Zonal management presents a number of advantages:

  • Reduces wiring complexity and complete wiring.
  • Enhances modularity and scalability, permitting modifications with out affecting your entire automobile.
  • Allows sooner, extra environment friendly coordination by way of high-speed Ethernet.
  • Improves response occasions, power effectivity, and security with distributed processing energy.

Zonal management models should stand up to electrical hazards like overcurrent, overvoltage transients, and ESD to stay operational. Including applicable safety parts to the circuitry ensures strong efficiency.

Zonal Management Unit (ZCU) Description

The ZCU interfaces with all forms of gadgets in its zone of management. Thus, it will possibly use many several types of communication protocols to interface with a variety of gadgets. Determine 2 illustrates the circuit blocks of a ZCU. Hazards that would harm the ZCU embrace overcurrent situations, transient voltages, and significantly ESD.

 Determine 2. Zonal management unit block diagram

Defending the DC/DC Converter 

The DC/DC Converter down-converts the 12 V enter to digital logic voltage ranges. Because the DC/DC Converter is the ability entrant to the ZCU, stopping harm from an overcurrent situation and maintaining voltage transients out of the circuit is crucial for dependable operation. 

Both a one-time fuse or a resettable fuse can present overcurrent safety. Think about a fast-acting, one-time fuse. Variations can open in lower than 5 s to a 250% overload. A large temperature vary is crucial for automotive functions. Fuses rated from -55° C to +150°C can be found. To save lots of house, choose a floor mount fuse, which might be in a small 1206 bundle. Additionally, select AEC-Q200-qualified parts for automotive functions each time potential. 

A polymer constructive temperature coefficient (PPTC) resettable fuse is an alternative choice to the one-time fuse.   A profit over a single-shot fuse is that PPTCs are resettable.  As soon as the overcurrent situation has cleared, the PPTC will return to a low-resistance state and reconnect the ability to the circuit.  AEC-Q200 variations can be found and are available in space-saving surface-mount packages. 

For voltage transient safety, significantly towards inductive transients reminiscent of inductive power discharges, both a steel oxide varistor (MOV) or a transient suppressor diode (TVS) can safely soak up their power. MOVs:

  • Can soak up load dump power as much as 25 J as required by SAE specification J1113
  • Have a large working temperature vary from -40° C to +125° C
  • Are AEC-Q200 compliant.

The choice element, fashions of TVS diodes, provide:

  • ESD safety to strikes as giant as 30 kV in accordance with IEC 61000-4-2
  • Absorption of peak energy pulses as much as 1500 W or surge currents as much as 200 A
  • Response occasions from below 1 ps to below 1 ns
  • A large working temperature vary of -65° C to + 150° C
  • Uni-directional or bi-directional fashions
  • Floor mount packaging
  • AEC-Q101 qualification. 

Defending the DC/DC Converter from overcurrent and transient voltage surges prevents these hazardous situations from propagating to downstream circuits, guaranteeing the ZCU processor is shielded from damaging power.

Defending the ZCU interface circuits

Within the high-noise, high-transient automotive setting, ZCU circuits interfacing with exterior gadgets by way of communication protocols or management drivers require ESD safety. Littelfuse presents a broad vary of ESD diodes and polymer parts tailor-made to totally different protocols, optimizing sign integrity whereas offering strong safety. Tables 1 and a couple of advocate ESD diodes for varied interfaces, with schematics displaying configurations. For RF circuits, the really useful ESD diode has the bottom capacitance and leakage present, minimizing sign distortion. Instance circuits illustrate TVS diode implementation for CAN and I/O interfaces.

 Desk 1.  ESD Diodes for LIN, CAN, and FlexRay interface ESD safety
Desk 2. ESD and TVS Diodes for RF, LVDS, Audio, I/O, LED, and Motor interface ESD safety

Defending the Automotive Ethernet bodily layer, the spine of zonal structure

Automotive Ethernet is now the principle communication interface in zonal management architectures resulting from its excessive information transmission charges, reaching as much as 10 Gb/s—far exceeding different automotive protocols. Present charges are usually 100 Mb/s and 1 Gb/s. Ethernet’s light-weight, two-wire twisted pair, strong error-checking, and scalability make it perfect for the cruel automotive setting and future necessities.

The push for Ethernet in zonal structure comes from the OPEN Alliance SIG, a non-profit group of automotive and tech suppliers selling Ethernet as the usual for automotive networking. The highest desk in Determine 3 lists varied “flavors” outlined by the alliance, whereas the decrease desk compares automotive Ethernet with CAN and LIN protocols.

Determine 3. Zonal communication construction and automotive Ethernet in contrast with different protocols

The OPEN Alliance has outlined particular necessities for shielding automotive Ethernet circuitry from ESD. Determine 4 exhibits an Ethernet transceiver circuit with the ESD safety gadget’s really useful location referred to as “1”. The adjoining desk lists the OPEN Alliance’s necessities for an ESD suppression gadget. (The ESD safety “2” has no relation to the OPEN Alliance SIG.)

Determine 4. OPEN Alliance SIG suggestion for ESD suppression implementation

Littelfuse has developed quite a few ESD suppression parts for Ethernet safety, together with one which particularly complies with the OPEN Alliance necessities. Along with assembly the necessities of the OPEN Alliance for an ESD suppression gadget, the Littelfuse answer has low capacitance to attenuate distortion of the Ethernet alerts and low leakage to attenuate power consumption. Desk 4 incorporates particulars on three choices for Ethernet safety. The Polymer ESD suppressor has the benefit of the bottom capacitance and the bottom leakage present. The 2 TVS diode arrays defend two information strains in a single bundle. All three parts exceed the really useful ESD safety degree referred to as out by the OPEN Alliance SIG.    They’re all AEC-Q certified; the Polymer ESD Suppressor to AEC-Q200 and the ESD Diodes to AEC-Q101.  The AQ24ETH-02HTG can be licensed to the OPEN Alliance specification.

Desk 4. ESD safety options which might be relevant to Automotive Ethernet.

Desk 5 compares the Polymer ESD Suppressor and one of many Diode Arrays with the OPEN Alliance necessities. Each exceed the OPEN Alliance’s ESD robustness towards harm degree. The OPEN Alliance has authorised the AQ24ETH-02HTG TVS Diode Array to guard 100Base-T1 and 1000Base-T1 transceivers from ESD strikes.

Desk 5. ESD suppression parts comparability with OPEN Alliance necessities (courtesy: Littelfuse)

Choose optimum parts for dependable and strong Zonal Management Items 

The zonal management unit’s circuitry wants to face up to {the electrical} hazards inherent within the extreme automotive setting. Designers can use the element suggestions for shielding the ZCU and all its interfaces to optimize their design course of. By figuring out safety parts early, in addition to consulting with a element producer’s utility engineers, designs can save improvement time and compliance prices. The appliance engineers can assist with the next:

  • Value-effective parts choice
  • Compliance to the relevant security requirements
  • Pre-compliance testing to keep away from compliance failure and save on delays and prices for a number of compliance take a look at cycles.

All of the Littelfuse parts offered are AEC-Q101 and AEC-Q200 certified. Utilizing these really useful parts will guarantee dependable and strong ZCUs with ESD-resistant interfaces.  

Obtain the Automotive Electronics Purposes Information to study extra about evaluating these safety suggestions, courtesy of Littelfuse.